KIST Develops Multi-Fascicular Artificial Nerve Conduit Mimicking Real Nerves
12-Month Tracking Study Conducted in Primates
Nerve Regeneration Induced Without Cells or Growth Factors
Potential to Replace Autologous Nerve Grafting

When multiple "paths" resembling actual nerves were created between severed nerves due to an accident, it was found that the nerves regrew and finger function was restored. This effect was demonstrated over the course of a year in primates whose hands are structurally and functionally similar to those of humans, suggesting the potential to supplement the current treatment method of autologous nerve grafting, which involves transplanting healthy nerves from other parts of the patient’s own body.


The Korea Institute of Science and Technology (KIST) announced on September 16 that a research team led by Youngmi Jung, principal investigator at the Biomaterials Research Center, along with Jongwoong Park’s team from Korea University College of Medicine and the National Primate Research Center at the Korea Research Institute of Bioscience and Biotechnology, has developed a "multi-fascicular nerve guidance conduit (MFNGC)" that mimics the actual structure of peripheral nerves.

The manufacturing process of a biodegradable nerve guidance conduit mimicking the actual bundle structure of nerves, and the implantation at the defect site of the median nerve in the wrist of a red-faced monkey. Provided by the research team.

The manufacturing process of a biodegradable nerve guidance conduit mimicking the actual bundle structure of nerves, and the implantation at the defect site of the median nerve in the wrist of a red-faced monkey. Provided by the research team.

View original image

When nerves in the hand or arm are severely damaged due to industrial or traffic accidents, patients may lose motor or sensory function in their fingers. If the gap between damaged nerve ends is large, the primary treatment is "autologous nerve grafting," which involves transplanting healthy nerves from another part of the patient’s body. However, this approach requires sacrificing healthy nerves, and the amount that can be harvested is limited.


Most conventional artificial nerve conduits are hollow tubes. In contrast, actual peripheral nerves are composed of multiple fine nerve fibers bundled together, meaning that existing conduits have limitations in guiding regenerating nerves in the proper direction.


The research team analyzed the nerve structure of the red-bellied monkey’s wrist and created three small channels within a larger conduit. The conduit was made from a flexible, biodegradable polymer material (PLCL) that gradually decomposes in the body. Without the use of separate cells or growth factors, the nerve-like structure itself was designed to induce regeneration.


15 mm severed nerves reconnected... Signals begin to return after 6 months


The researchers surgically removed 15 mm of the median nerve in the monkey’s wrist, implanted this conduit, and tracked nerve regeneration and hand function over a 12-month period.


As time progressed, the monkeys’ time to grasp small food items with their fingers decreased and their scores for movement impairment improved. Electromyography testing showed that, in most cases, signals returned from about six months after surgery.

Structure of a nerve guidance conduit that implements multiple nerve regeneration pathways by mimicking the bundle structure of the red-haired monkey's vagus nerve. Provided by the research team

Structure of a nerve guidance conduit that implements multiple nerve regeneration pathways by mimicking the bundle structure of the red-haired monkey's vagus nerve. Provided by the research team

View original image

Twelve months after implantation, newly regenerated nerves within the conduit were organized into multiple bundles, closely resembling natural nerves, and the myelin sheath surrounding the nerve fibers had been regenerated. The molecular weight of PLCL used in the conduit decreased by about 94% compared to pre-implantation levels, and no significant chronic inflammatory reactions were observed. This confirmed that the conduit served as a guide for regenerating nerves and was gradually degraded in the body.


The research team explained that there are advantages for medical device development, since it does not require cell culture, additional growth factors, or cryopreservation. With further validation studies, manufacturing process standardization, and regulatory approval, the device could be developed into a nerve regeneration medical solution that overcomes the limitations of autologous nerve grafting.


Youngmi Jung, principal investigator at KIST, said, "We have verified the regenerative potential of artificial nerve conduits mimicking the fascicular structure of real nerves in primates, whose hand structure is similar to that of humans," and added, "We plan to expand our validation studies and pursue clinical applications for domestically developed nerve regeneration medical devices."



The results of this study were published in the latest issue of the international journal 'Bioactive Materials.'