Mechanical Performance Improved Through Simultaneous Optimization of Porous Structure and Implantation Angle
Reflecting Bone Microstructure: Offering the Potential for Patient-Specific Medical Device Design

The research team led by Professor Jeongjin Kim in the Department of Mechanical Engineering at Keimyung University (President: Shin Ilhee) has proposed a design technology for patient-specific bone tissue regeneration scaffolds, and published their findings in the internationally renowned journal "Expert Systems with Applications."


The title of the paper is "Optimal design of specific patient porous structure and implantation angle of bone scaffolds in the two-dimensional proximal femur," and the study is recognized for addressing the limitations of existing medical device design by reflecting patient-specific bone microstructure and mechanical properties.

Junwon Choi, PhD candidate in the Department of Mechanical Engineering, and Jeongjin Kim, professor in the Department of Mechanical Engineering. Provided by Keimyung University

Junwon Choi, PhD candidate in the Department of Mechanical Engineering, and Jeongjin Kim, professor in the Department of Mechanical Engineering. Provided by Keimyung University

View original image

This journal is ranked in the top 6.1% in the JCR category of Operations Research & Management Science. (doi.org/10.1016/j.eswa.2025.130784)


An artificial scaffold is a structure inserted into a damaged bone area to support regeneration. Bone defects exceeding a critical size cannot heal naturally, making structural replacement essential.


Autografts and allografts have been criticized for their supply limitations, as well as issues such as infection and immune response.


There has also been a recognized need for improvement in scaffold design.


If the mechanical properties of the scaffold do not match those of the surrounding bone tissue, either overload or underload may occur, which can hinder healing.


As a result, the necessity for precision design that takes into account each patient's bone structure has been consistently emphasized.


The research team constructed a two-dimensional finite element model of the proximal femur based on medical imaging data and analyzed structural behavior under actual loading conditions.


Based on this, they applied a genetic algorithm to derive a design method that simultaneously optimizes the pore size and implantation angle of the scaffold.


The results showed that the optimal pore structure and implantation angle varied depending on the implantation site, and the optimized scaffold exhibited improved adaptability to external loads.


This demonstrates that patient-specific design can lead to actual improvements in mechanical performance.


Professor Jeongjin Kim stated, "The optimal design of patient-specific artificial scaffolds is a research achievement that was difficult to realize with existing technology," adding, "It is highly significant as a design technology that reflects bone microstructure and mechanical environment."


Junwon Choi, a PhD candidate who participated in the research, said, "Designs that reflect patient-specific characteristics can overcome the limitations of conventional uniform scaffold designs," and added, "This can be further expanded to three-dimensional precision medical device design in the future."


In this study, Junwon Choi participated as the first author, and Professor Jeongjin Kim served as the corresponding author.



The research was conducted as part of the Excellent Young Researcher Program supported by the Ministry of Science and ICT and the National Research Foundation of Korea.


This content was produced with the assistance of AI translation services.